Mifare 14443A Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Fernsehantennen Mifare 14443A herunter. Mifare 14443A Datasheet Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - MiFare Protocol Guide

MiFare Protocol Guidefor metraTec MiFare Readers and ModulesDate: June 2009Version: 1.0metraTec MiFare Protocol Guide

Seite 2 - Table of Content

3.4. Wake Up (WAK)The wake up command ends the power save mode. Reader will restore its last state prior to the standby. If successful it returns GMO

Seite 3

e.g. Set pin 0 high: WOP<SPACE>00<SPACE>HI<CR>e.g. Set pin 0 low: WOP<SPACE>00<SPACE>LOW<CR>Response, if succe

Seite 4 - List of Abbreviations

3.8. Cyclic Redundancy Check Off (COF)This command turns off the Cyclic Redundancy Check (CRC) of the computer-to-reader communication. This is the de

Seite 5 - 1. Introduction

SSK<SPACE>23<SPACE>FFFFFFFFFFFF<CR>Possible Error Response:UPA<CR> Unknown parameterEDX<CR> Location fail, or other cha

Seite 6 - 1.2.Further Documents

SKU<SPACE>{Type}<SPACE>[Loc]<CR>Parameter DescriptionType The type of the key:TEMP chooses the temporary keySTAT chooses the static

Seite 7 - 2. Communication Principle

4. General ISO 14443A CommandsThis list gives an overview of the existing commands that can be used with any transponder that is based on ISO14443A,

Seite 8 - 3. Reader Instructions

IVF 02<CR>Possible error codes:UPA<CR> Unknown parameter4.2. Select Tag (SEL)Before you can exchange data with a MiFare chip, the transpo

Seite 9 - 3.3. Standby (STB)

Sometimes it is useful to work with all cards in the field. For this purpose an optional parameter “CYC” exists. When using the “CYC” parameter it is

Seite 10 - 3.6. Write Output Pin (WOP)

C2DF6084<CR>Possible error codes:UPA<CR> Unknown parameterTNR<CR> Tag not responding (left the field since the INV command)4.3. Rea

Seite 11

CMD Custom Read Command, one hexadecimal byteTable 5: Read command parameter descriptionResponse, if successful:Number of lines is equal to the number

Seite 12 - 3.9. Save Static Key (SSK)

Table of ContentList of Abbreviations...4

Seite 13 - 3.11. Set Key to Use (SKU)

command also has a direct write mode, marked with the first parameter “DRT”. The number of bytes will not be checked in this mode and it depends on th

Seite 14

WDT<SPACE>00112233445566778899AABBCCDDEEFF<SPACE>18<CR>Possible error codes:UPA<CR> Unknown parameterEHX<CR> The string

Seite 15 - 4.1. Inventory (INV)

5. MiFare Classic CommandsThis section describes commands only to be used with MiFare Classic (1K or 4K) chips.Command Name DescriptionAUT Authentica

Seite 16 - 4.2. Select Tag (SEL)

Response, if successful:OK!<CR>Examples:Direct authentication of block 8 (sector 2) with keytype B and key FFFFFFFFFFFFhAUT<SPACE>DRT<S

Seite 17

Block 13 (sector 3) is authenticated and all blocks of this sector should be returnedGAB<SPACE>ALL<CR>Response:0 1 0<CR> (Block 12 i

Seite 18 - 4.3. Read Data from Tag (RDT)

There are different ways to manipulate data in the sector trailer by using these modes: Set key and Access Bits (SKA) Set Keys Only (SKO) Direct ov

Seite 19 - 4.4. Write Data to Tag (WDT)

Examples:Write Key A (665544332211), Key B (112233445566) and block mode 3 (1 1 0) for block 2STM<SPACE>SKA<SPACE>2<SPACE>1<SPAC

Seite 20 - OK!<CR>

C1, C2, C3 BCD-Coded Mode, 0 or 1KeyA MiFare authentication key A; 6 Bytes hexadecimal coded ASCII-string (16 chars)KeyB MiFare authentication key B;

Seite 21

 Increment - adds a value (given as parameter) to the value present in a chosen block (inputblock) and writes the result to the outputblock. (Mode 3)

Seite 22 - 5. MiFare Classic Commands

VAL<SPACE>INIT<SPACE>SAB<SPACE>00202000<SPACE>05<CR>Possible error codes:UPA<CR> Unknown ParameterNMA<CR> No

Seite 23 - 5.2. Get Access Bit (GAB)

5.2. Get Access Bit (GAB)...235.3. Sector Trailer Manip

Seite 24

Parameter DescriptionMOD Selected either increment (INC) or decrement (DEC) VALUE unsigned hexadecimal value (summand/subtrahend)Inputblock 1 decimal

Seite 25

5.4.3. RestoreThis command is used for powerful backups. If the input –and outputblock are not the same, this command restores the result written in t

Seite 26 - 5.3.2. Set Key Only (SKO)

6. AppendixAppendix 1: CRC Calculation// this function calculates a CRC16 over a unsigned char Array with, LSB first// @Param1 (DataBuf): An Array, w

Seite 27

BNW Block Not WritableBAE Block Access ErrorBNA Block Not AuthenticatedAKW Access bits or Keys not WritableUKB Use Key B for authenticationUKA Use Ke

Seite 28

Sector Block Absolute Block Nr Funktion15 3 63 Sector Trailer (Key A, access bits, Key B)15 2 62 Data15 1 61 Data15 0 60 Data… … … …0 3 3 Sector Trail

Seite 29

one or both of the keys for each block. That means, that e.g. you can use Key A in your customer application which is only able to read the data, but

Seite 30

Block Mode 0: This is the transport configuration (delivery state). In this mode the block is readable and all data manipulating commands are enabled.

Seite 31 - 5.4.3. Restore

7. Version ControlVersion Change by Date1.0 created KD 11.3.2009metraTec MiFare Protocol Guide

Seite 32 - 6. Appendix

Contact / SupportmetraTec GmbHWerner-Heisenberg-Str. 1D-39106 MagdeburgTel.: +49 (0)391 251906-00Fax: +49 (0)391 251906-01Email: [email protected]

Seite 33 - Memory Organisation

List of AbbreviationsATQA Answer to request, ISO 14443A – a number code showing some information on the card. See Appendix for examples.PICC Proximity

Seite 34 - Access Rights

1. IntroductionThis document describes the metraTec firmware protocol for all metraTec RFID readers that work with RFID transponders according to ISO

Seite 35

1.2.Further DocumentsFor an even deeper understanding of the operating principle it might be useful to read all datasheets and norms regarding your tr

Seite 36

2. Communication PrincipleThe communication between the reader and the host system is based on ASCII strings. Each string is terminated with a carria

Seite 37 - 7. Version Control

3. Reader InstructionsThis list gives an overview of all the existing instructions that directly influence the reader itself. All commands that are c

Seite 38 - Contact / Support

3.2. Revision (REV)The revision command requests the device type and hard- and software revision of the reader. The reader returns its device type and

Kommentare zu diesen Handbüchern

Keine Kommentare